Printable View
|
 |
| ID 200 Series |
| Interface Concentration Detector System |
|
SYSTEMS:
- ID-201 (½ Inch Shaft)
- ID-202 (1 ¼ Inch Shaft)
- ID-205 (Cable Mounted)
|
|
Description
The ID-200 Series Interface Detectors are used for interface measurement and control in all types of liquid/liquid and vapor/liquid separation processes including emulsions and foam. A wide range of models, process connections, and output options are available for the control of a variety of process installations such as Tanks, Decanters, Dehydrators, Desalters, Coalescers, etc. The ID-200 Series advanced control capabilities can be used to automate upset responses, antifoam and demulsifier chemical feed systems, and eliminate cross-contamination of separating phases.
|
| Emulsion Concentration |
0-100% Hydrocarbon/ Water by Volume |
| Process Temperature |
Standard: 32°F to 300°F (0°C to 149°C) High-Temp: 32°F to 450°F (0°C to 232°C) |
| Ambient Temperature |
-40°F to 131°F |
| Pressure Rating |
Up to 3000 PSI |
|
|
| Materials Of Construction |
| Probe |
316 Stainless Steel, Teflon & Peek |
Duplex, Hastalloy, Monel (Others available upon request) |
| Seals |
Aflas and Teflon |
Viton |
|
|
| SH-2"/SS |
2" NPT Seal Housing, 316 Stainless Steel |
| SH-2"/SS |
2" NPT Seal Housing, Carbon Steel |
| CF-¼"/SS |
¼" NPT Compression Fitting, 316 Stainless Steel |
| CF-¼"/CS |
¼" NPT Compression Fitting, Carbon Steel |
| Flange Connections |
ANSI 150# to 1500# |
|
|
 |
| ID-201 Components: Probe, Seal Housing & Power Supply Nema 4/7 Enclosure |
|
|
|
| ID-201 |
½" shaft; Standard: 48" (4 Ft.); Minimum: 12" (1 Ft.); Maximum: 120" (10 Ft.) |
| ID-202 |
For probe lengths greater than 10 feet, sturdier 1 ¼" shaft assemblies from 5 foot sections via threaded connections. |
| ID-205 |
Shaft replaced by cable for suspension of antenna down through the top of the tanks, wells, platform legs, caverns, etc. |
|
|
| ID-201, ID-202, ID-205 Probe |
Intrinsically Safe: Class 1, Div.1, Groups C & D, T3C ATEX: II 1G EEx ia IIB T4 (-40ºC<Ta<+70ºC) II 1G EEx ia IIC T5 (-40ºC
|
| Power Required |
115/240 VAC 50-60 Hz or 12/24 VDC (±20%) Normal Power Consumption 3 Watts Maximum Power Consumption of 250 Watts (including lights) |
| PS-201 Enclosures |
Weatherproof (N4X) NEMA 4X Explosion Proof (N4/7) NEMA 4/7 Class 1, Div. 1, Groups C&D |
| Wiring Connections |
Flame-Proof (N4/7) NEMA 4/7 ATEX: II 2G Ex d[ia] IIB T6 (-20ºC<Ta<+55ºC) Barrier Terminal Block #18 AWG Maximum Diameter |
|
|
| ID-201/420 |
Powered 4-20 mA into 400 Ohms Maximum; 4 mA = Oil, or Lowest Water Content |
| ID-201/RL |
Relay Contact 1A; 115V; NO and NC; (SPDT); Fail Safe On Water or Oil Adjustable Trip Point |
| ID-201/RL/420 |
Relay and 4-20mA Options |
| ID-201/RL/LI |
Relay with Local Indicating Lights; Amber = Oil, Blue = Water |
|
|
CERTIFICATIONS
CSA-US Canadian Standards Association /UL Specifications ATEX European Committee for Electrical Standardization GOST-R Russian Approval, ROSTECHNADZOR Safety JRIIS Japanese Research Institute of Industrial Safety
|
 |
|
|